Incinerator to cut black bag landfill waste
30 August 2013 Last updated at 21:18 BST
30 August 2013 Last updated at 21:18 BST
Top Openning Door Waste Incinerators Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC) Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto. Combustion Chamber 1200L 1500L 2000L 3000L Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm Secondary Chamber 600L 750L 1000L 1500L Smoke Filter Chamber Dry Scrubber Dry…
Model CA-200 Picture Burning Rate Average 100 kgs/hour Primary Combustion Chamber 2000 Liters Secondary Combustion Chimney Yes Feed Mode Manual Voltage 220V Power 3.0 Kw Fuel Type Diesel Oil Burner Italy Original Oil Consumption (Diesel Oil) Average 53 kg/hour Internal Dimensions 230 x 100 x 90cm (primary chamber) External Dimensions 290 x 200 x 170cm…
Item Specification Model YD-20C Main Product List Primary Combustion Chamber Secondary Combustion Chamber Mix-Combustion Chamber Smoke Filter Chamber Incinerator Control Case Chimney:5.0Meters *(upgrade to Stainless Steel, free cost) Italy oil burner: 02 sets Oil Tank: 100Liters Optional: Mobile Trailer for Incinerator Phone: +86-13813931455(whatsapp/wechat)Website: http://www.hiclover.com/ Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. bio medical waste management ppt 2020 HICLOVER Incinerator/Parts Range Main Feature Medical…
Items/Model TS800 Picture Principle Animal Waste Incineration Treatment Burn Rate Average 300-450 kg/hour Feed Capacity Average 1200kg/feeding Control Mode Electric Control Combustion Chamber 3000Liter Internal Dimensions 300*100*100 cm Secondary Chamber *** Feed Mode Manual/Forklift Voltage 220V/380V Power 5.0Kw Oil Consumption (kg/hour) ***waste to energy plants cost Gas Consumption (m3/hour) Ave.22.8m3n/hr Temperature Monitor Digital Display Temperature Protection Yes…
Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range…
A flue chimney, 15,000mm long and 560mm diameter shall be constructed from steel sheet, complete with lagging, damper and rain water protection cone. The chimney shall be lined with castable grade diatomaceous concrete mixed with high alumina cement in accordance with BS 4076: 1989. The damper will control the closing of the door to not…