Solid Waste Incinerators
The Contractor shall provide a Cremation System package for TWO (02) Cremators and system approved by related authority, which must fit into the allocated area as shown on the plan drawings. The work shall include but not limited to design preparation, authority design approval, supply, fabricate, construct, commissioning, testing, operational approval, provide training and also…
Medical waste incinerator 100kgs Model TS100
incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator Items/Model TS100 Burn Rate Average 100 kg/hour Feed Capacity Average 200 kg/feed Control Mode PLC Combustion Chamber 1200L Internal Dimensions 120x100x100cm Secondary Chamber 600L Smoke Filter Chamber Yes Feed Mode Manual Voltage 220V Power 0.7Kw Oil Consumption (kg/hour) 14–28 Gas Consumption (m3/hour) 10–32.2 Temperature Monitor Yes Temperature Protection…
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS
Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core HICLOVER – Medical Environmental WWW.HICLOVER.COM Waste Incinerators Medical Waste Incinerator Pet Animal Cremation Solid Waste Incinerator Tel: +86-25-8461 0201 Mobile: +86-13813931455(whatsapp/wechat)Website: www.hiclover.com Email: [email protected]Email: [email protected] Nanjing Clover Medical Technology Co.,Ltd. 2020-06-27 smart [ecwid widgets=”productbrowser search categories” default_category_id=”CATEGORY_ID” default_product_id=”PRODUCT_ID” lang=”EN”]
small scale medical waste incinerator
Toxic and dangerous wastes, Medical pharmaceutical and hospitable liquids Wastes Domestic garbage Electric and electronic wastes Industrial wastes In General, all type of wastes and garbages Capacity 50-60Kg/h Combustion supporting materials Coal oil, diesel oil Temperature inside 800-10000C 1000-12000C Burning efficiency >98% Power consumption 1.3KW Noise <78dB Index of let smoke and waste gas Ringelman’s…
incinerator manufacturer 200kgs/h
Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste: * Perfectly tight door for the manual loading of waste. The loading should be…
medical incinerators
* medical incinerators, The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on the outside sheet metal. * Composition of the refractory; ? Refractory concrete : ? . Thickness : ≥100 mm ? . Nature: 42%…